DC/AC 80A-1600A 3 Pole 4 Pole Moulded Case Circuit Breaker Ns Nsx MCCB

Model NO.: NS NSX
Poles Number: 3
Type: Circuit Breaker
Function: OVP(Overvoltage Protection)
Certification: CE
Rated Working Voltage: 690V
All Standard: IEC947-2
Model Number: Ns/Nsx
Typ E: Moulded Case
Poles: 3/4 Pole
Quality: Stable and Reliable
Different Type for Selection: According to Customer Demand
Rated Current: 12.5A-1600A
Rated Voltage: 690V
Shunt & Under Voltage Coil: Mx/Mn
Trademark: suntree
Transport Package: Stand
Specification: 100~1250
Origin: Zhejiang China
HS Code: 853662000
DC/AC 80A-1600A 3 pole 4 pole Moulded Case Circuit Breaker Ns NSX MCCB
 

Application of  MCCB                                                                                 

 

SM6(NSX) MCCB is suitable for using in the circuit of AC 50/60Hz, please make remarks when ordering, rated insulating voltage 750V, rated working voltage below 690V, and rated current is 16A to 1250A for distributing electric energy, and infrequently OFF/ON under normal condition. The intelligent MCCB, which the rated frame rank current is 800A and below, also can be used for infrequently switching and starting of squirrel cage motor and for protecting motor from over-load, short circuit and under-voltage. 

 

Working conditions of MCCB                                                  

1. Not over altitude 2000m; 

2. Ambient temperature is between-25°C and +40°C ; Working in the medium which not any   explosive, not enough dielectric to corrode metal, no gas to damage insulation and electric conduction dust; 

3. Working in the place would not be invaded by rain and snow; 3. Pollution degree3;         4. Mounting type. 

 

Classification of MCCB                                                             

1) According to using: distribution circuit protection type, motor production type;

2) According to connection mode: front panel connection, back panel connection, plug-in connection;

3) According to operating way: for direct handle operating, for motor operator operating, for rotary handle operating.

4) According to the number of pole: 3,4 pole.

5) According to the accessory: with accessory setting, and without accessory setting.
 

The Main Capability Index of MCCB                    

 

the protection of SM6 serise breakers(intelligent)

 

The frame current grad(A) Rated current Times of short delay(times) Notice
100model(SE) 40-100 2-10

1: Grades to adjust:2,3,4,5,6,7,8,10

2: Rated current can be adjusted, and has 48 grades.

3:Distribute electric instantaneous multiple up from 11 times.

4: Motor instantaneous multiple up from 12 times

160model(SE) 64-160 2-10
250model(SE) 100-250 2-10
400model(SE) 160-400 2-10
630model(SE) 250-630 2-10
1250model(SE) 500-1250 2-10

 

NS/NXS MCCB Technical Data

 

Type

Pole 
number

Rated
 insulating

 voltage(V)

Rated 

operating

 voltage(V)

Rated ultimate

 short circuit breaking 

capacity Icu 

(KA) at 380/415V

Rated servies 

short circuit breaking

 capacity Ics at

 380/415V(KA)

Operation 

performance

Utilization

 category

ON

OFF

NS-100N

3, 4pole

750

690 and below

25

25

1500

8500

A

NS-100H

70

70

NS-100L

150

150

NS-160N

36

36

1000

7000

NS-160H

70

70

NS-160L

150

150

NS-250N

36

36

1000

7000

NS-250H

70

70

NS-250L

150

150

NS-400N

45

45

1000

4000

NS-400H

70

70

NS-400L

150

150

NS-630N

45

45

1000

4000

NS-630H

70

70

NS-630L

150

150

NS-1250N

3 pole

50

37.5

1000

4000

NS-1600N

50

37.5

 

Type

Rated currentIn(A)

Note

NS-100

12.5,16,20,25,32,40,50,63,80,100

Tadjustable (0.8~1In)M adjustable (5~10In)

NS-160

16,20,25,32,40,50,63,80,100,125,160

NS-250

160,180,200,225,250

NS-400

315,350,400

NS-630

400,500,630

NS-1250

800,1000,1250

Tadjustable (0.8~1In)M fixed

NS-1600

1000,1250,1600

 1. Overload protection with adjustable threshold, as defined by IEC60947-22. Short-circuit protection with adjustable threshold3. Instantaneous short-circuit protection4. Earth fault protection with adjustable threshold5. Load indication : light at 90% of Ir setting threshold; Flashing more than Ir setting threshold6. Fault indicationLEDs indicates the type of fault that caused trippingOverload  (LT protection) or abnormal component temperature (>Ir);Short-circuit (ST or instantaneous protection)( >Im);Earth fault (if earth fault protection option is present)(Ig);Microprocessor malfunction (both (>Ir) and ( >Im) LEDs go on ,plus the (Ig) LEDs if earth fault protection option is present )Battery powered. Spare battery are supplied in an adapter box. When a fault occurs , the LED indicating the type of fault , lights for about 10 minutes . The information is however stored in memory .  The LED can be illuminated by pressing the test pushbutton.  The LED automatically goes off and the memory is cleared when the circuit breaker is reset .

 

Type

Rated current In(A)

Note

NS-400

400

Ir=0.4~1×In(adjustable 48 setting)Tripping between 1.05~1.3×Ir (IEC60947-2)at 6×Ir Trip time: 1s, 2s, 4s, 8s, 16s(adjustable)(Long-time overload protection)Isd=1.5-2-3-4-5-6-7-8-10×IrTrip time: 0s, 0.1s, 0.2s, 0.3s adjustable+I2t(Short-circuit short time delay protection)Ii=1.5-2-3-4-6-7-8-10-11×Ir(Instantaneous short-circuit protection)Ig=0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8-1×IrTrip time: 0.1s, 0.2s, 0.3s, 0.4s adjustable+I2t(Earth fault protection) (If option is present)

NS-630

630

 

4.Accessories

 

Accessories

Rated operating voltage

Consumption

For type

Pick-up

Seal-in

Shunt release(MX)

24V100V220/230V380/400V

<10VA

<5VA

NS-100~630

Under-voltagerelease(UN)

220/230V380/400V

<10VA

<5VA

 

 

Accessories

Rated operating voltage

Consumption

For type

AC12

AC15

Auxiliary contact(OF)

380/400V

6

3

NS-100~630

Alarm contact(AL)

380/400V

6


Rotary handle
Direct rotary handle
Degree of protection:IP40 
Function: 
1) suitability for isolation 
2) indication of three positions 0(off) I(on) and tripped 
3) press "push to trip" button, can trip-free
4) visibility of and access to trip unit settings 
5) the circuit breaker can be locked in the off position by one to three padlocks , diameter 5 to 8mm(not supplied)
Extended rotary handle
Degree of protection:IP55
Function: 
1) Suitability for isolation
2) Indication of three positions 0(off) I(on) and tripped
3) Visibility of and access to trip unit settings when the door is open
4) Door opening prevented when circuit breaker is on
5) The circuit breaker can be locked in the off position by one to three padlocks , diameter 5 to 8mm(not supplied).Locking prevents opening of the switchboard door

5.Installation
Circuit breaker may be mounted vertically, horizontally or flat on their back without any derating of characteristics.
6.Fix
Mounting on backplate , mounting on rails
7.Connection
Front panel connection , black panel connection , plug-in connection 
8. Outline and Installation Dimension

 
mm C C1 C2 C3 G G1 G4 G5 H H1 H2
NS 100/160/250N/H/L 29 76 54 108 62.5 125 70 140 80.5 161 94
NS 400/630N/H/L 41.5 116 92.5 184 100 200 113.5 227 127.5 255 142.5
 
mm H3 H4 H5 H6 H7 K K1 K2 L L1 L2 P1 P2 P4 P5
NS 100/160/250N/H/L 188 160.5 321 178.5 357 17.5 35 70 52.5 105 140 81 86 111* 83
NS 400/630N/H/L 285 240 480 237 474 22.5 45 90 70 140 185 95.5 110 168 107
 
mm P6 R R1 R2 R4 R5 ΦT ΦT4 (Ue)
NS 100/160/250N/H/L 88 14.5 29 54 108 143 6 22 ≤32
NS 400/630N/H/L 112 31.5 63 71.5 143 188 6 32 ≤32


SM8max MCCB

 
Type SM8max-160 SM8max-250 SM8max-400 SM8max-630
Poles 3 3 3 3
Rated current In(A) 16-160 100-250 250-400 400-630
Rated operating voltage Ue(V)(50/60Hz) 690
Rated insulation voltage Ui(V) 800
Rated impulse withstand voltage Uimp(kV) 8
Utilisation category A
Frequency withstand voltage 1 Minute 3000 3500
Rated limited short-circuit breaking capacity Icu(kA) 220/230V 25 50 70 70
380/415V 16 36 36 36
400V 10 25 30 30
500V 8 20 25 25
690V 3 5 20 20
Rated operating short-circuit breaking capacity Ics (100% Icu) 220/230V 100% 75% 100% 100%
380/415V
400V
500V
690V
Rated short-circuit closing capacity Icn(kA) 220/230V 52.5 105 154 154
380/415V 32 75.6 75.6 75.6
400V 17 52.5 63 63
500V 13.6 40 52.5 52.5
690V 4.3 7.7 40 40
Mechancial life Operating recycle times 25000 2000
Operating recycle times per hour 240 120
Electrical life Operating recycle times 8000 6000 5000
Operating recycle times per hour 120 60
 



DC/AC 80A-1600A 3 Pole 4 Pole Moulded Case Circuit Breaker Ns Nsx MCCB
DC/AC 80A-1600A 3 Pole 4 Pole Moulded Case Circuit Breaker Ns Nsx MCCB

DC/AC 80A-1600A 3 Pole 4 Pole Moulded Case Circuit Breaker Ns Nsx MCCB
FAQ:

Q:  What's your warranty ?
 A: Two years

Q:  How can i trust you and your company ?
A: Suntree is a group company, we have 6 subcompanies. 
Have cooperation with 
LS, EKF the world-class companies. 
Our company over 500 employees, products pass 
CE,IEC,TUV,SAA, RCM, ROHS certificates. 


Q: What's your contact information:
A: Our address: Liushi town, Zhejiang province, China. 

Q: What's your shipment method?
A: We ship by Express, by air, by sea, by train. Normally we checked and compare, 
then provide customer the most proper shipment method.


Q: What's about MOQ?
A: First order MOQ=1pcs

Q: If i want to release order, what's the payment method you accept ? 
A: We accept T/T, Paypal, Western union, L/C.

 Q: If i want to release order, what's the process?
A: Thanks. You can send inquiry to us by made-in-china, 
or send us by email, we will reply within 24hrs.


 Thank you & Now pls send your inquiry !  ^!^ 

Desktop Power Adapters are indispensable as a source of DC voltage for an entire range of electronic devices. The provided power of 24W to 200W and output voltage from 5 to 56V covers the requirements of all typical uses. The principal areas of use are telecommunications, payment terminals and cashier systems, neon signs, diagnostic equipment, security systems and others.

Desktop AC/DC Adapter

Desktop Adapter,Desktop Ac Adapter,Desktop Dc Adapter,Desktop Ac/Dc Adapter

Meile Group Limited , http://www.hkmeile.com

This entry was posted in on